Insulation thickness/surface temperature - Heat Transfer & Thermodynamics engineering (2024)

×

INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS

Thanks. We have received your request and will respond promptly.

Log In

Come Join Us!

Are you an
Engineering professional?
Join Eng-Tips Forums!

  • Talk With Other Members
  • Be Notified Of Responses
    To Your Posts
  • Keyword Search
  • One-Click Access To Your
    Favorite Forums
  • Automated Signatures
    On Your Posts
  • Best Of All, It's Free!

Join Us!

*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail.

Posting Guidelines

Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Students Click Here

Eng-Tips Posting Policies

Contact US

thread391-262608

ForumSearchFAQsLinksMVPs

Insulation thickness/surface temperature

Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

Hi,

I have a Excel sheet wich calculates the insulation thickness, so that the surface temperature reaches, a user defined temperature, for example 40ºC, for safety reasons.
It happens 2 things that i consider quite strange:

1) What some people say is that as lower is the pipe diameter the less would be the insulation thickness, to reach the same surface temperature. Well, what i found is the opposite, as i insert bigger diameters, the insulation thickness increases very very much, even to stupid values...
We can see that also from the equations: as we increase the pipe diameter for the same insulation thickness, the LN(r2/r1) decreases and the heat transfer coeffecient increasesm, therefore the heat loss also increases.
I would like to see some comments.

2) i have a little macro wich uses the goal seek function, and it change increases the insulation thickness until the surface temperature lowers to the specified value: 40ºC. The problem is that excel finds a value wich represent a surface temperature value, not exact. The deviation error goes from 5 to 20%. This is very strange and is the 1st time that it happens to me. Manually, i have no problem to find the exact value. What maybe occuring?

Thanks

RE: Insulation thickness/surface temperature

ione (Mechanical)

Further to your 1st question, both you and "some people" are saying the same thing.

The heat transfer through insulation (and just through insulation) is governed by conduction.

Q = 2*pi*L*k*DeltaT/ln(d2/d1)

Where:

Q = heat flow through insulation [W]
k = insulation thermal conductivity [W/(m°C)]
DeltaT = temperature difference between outer and inner surface of the insulation [°C]
d2 = outer insulation diameter [m]. d2 is equal to the pipe diameter + twice the insulation thickness
d1 = inner insulation diameter [m]. d1 is equal to the outer pipe diameter

This is an increasing function (just differentiate with respect to d1) and so heat increases as pipe diameter increases.

Further to your 2nd if you could post your spreadsheet maybe someone could help you.

RE: Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

Dear Ione,

thank you very much for your answer.
Thas correct, it follows my idea and my analysis of the equation!

In relation to the second point, i found the problem. I was using a ABS() function to give positiva values, and it was messsing with the results. I removed it and the results now are fine!!

thanks, i think it's all cleared!!

RE: Insulation thickness/surface temperature

ione (Mechanical)

Marcosdias,

As you know the overall heat transfer coefficient involves also convection at the inside pipe surface, conduction trough the pipe thickness, conduction through insulation thickness and convection at the outside insulation surface (pls. see the attached pdf). The heat transfer is the results of four processes (thermal resistences in series), and also inside and outside convection coefficients (hi and ho) are influenced by the pipe diameter.

RE: Insulation thickness/surface temperature

25362 (Chemical)

Then, of course, there is another strange result. If the ratio k/h of conductivity k (W/m.K) to the external convection coefficient h (W/m2.K), is greater than the outer radii (including insulation) an increase in insulation thickness will cause an increase in heat transfer. Generally applicable to wires and very small diameter tubes.

RE: Insulation thickness/surface temperature

AllHandlesTaken (Mechanical)

As a side -

There is a good insulation program available for free to calculate all these things:

http://www.pipeinsulation.org/

RE: Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

Dear AllHandlesTaken,

I know, but the 3E Plus is a bit strange it gives strange results i have gaven up of using it.

RE: Insulation thickness/surface temperature

ione (Mechanical)

marcosdias,

Try the link below

http://www.kaimann.de/en/service/kaicalc.html

There is a freeware program for insulation which works well (it deserves a star!)

RE: Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

Dear ione,

Thank you for the link, but i can't download it because Kaimann links are broken

I will try again later

RE: Insulation thickness/surface temperature

ione (Mechanical)

marcosdias,

The link has been out of service for a couple of days, but now it is operative: give it a shot!

RE: Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

Great IONE,

thanks for the post!
I'm downloading it.
I will give my opinion later.

P.S.: My excel worksheet is finished and it's working fine.
Maybe i will share it later, when i have time to translate it to english, becaus is in Portuguese...

Thanks!

RE: Insulation thickness/surface temperature

zekeman (Mechanical)

") What some people say is that as lower is the pipe diameter the less would be the insulation thickness, to reach the same surface temperature. Well, what i found is the opposite, as i insert bigger diameters, the insulation thickness increases very very much, even to stupid values...
We can see that also from the equations: as we increase the pipe diameter for the same insulation thickness, the LN(r2/r1) decreases and the heat transfer coeffecient increasesm, therefore the heat loss also increases.
I would like to see some comments."

"Some people" are wrong and you are right
Another way of looking at this is the thermal resistance through the insulation is
ln(ro/ri)/(2piK)
Now keeping the temperature constant at the outside surface demands that the resistance be the same. Looking at the above expression it is seen thatthe resistance is constant when ro/ri ic constant. So for increasing ri the difference ro-ri must increase, proving your results.

RE: Insulation thickness/surface temperature

rmw (Mechanical)

Marcosdios,

Go ahead and post it as is for those of us who speak Portuguese.

rmw

RE: Insulation thickness/surface temperature

davefitz (Mechanical)

another trick that can be used to minimize insulation thickness: standard aluminum pipe lagging may have an emissivity of 0.10, but if you use anodized aluminum lagging, the emissivity is 0.90. The use of anodized lagging would allow muchthinner insulation based on radiative cooling.

RE: Insulation thickness/surface temperature

marcosdias (Mechanical)

(OP)

dear davefitz,

I'm quite confused about what you've said.

In the radiation heat transfer equation, if you increase the emissivity, you increase the heat transfered. so, how do you lower the insulation thickness??

Thanks for the post!

RE: Insulation thickness/surface temperature

ione (Mechanical)

RE: Insulation thickness/surface temperature

davefitz (Mechanical)

The increase in heat transfer rate at the surface serves to lower the surface metal temperature. In the case where the objective is to prevent harming a worker due to a high surface temp, using anodized aluminum will reduce the required insulation thickness. However, the loss of heat from the piping to the environment will increase,causing the root process to consume more energy.

RE: Insulation thickness/surface temperature

ione (Mechanical)

It is true that low lagging emissivity increases outer surface temperature at a given insulation thickness. Consequently increasing the jacket emissivitythe outer surface temperature drops. Anyway the trade-off is quite expensive as the heat dissipated increases. I would prefer to use warning signals to inform personnel about risks related to hot surface contact.

Red Flag Submitted

Thank you for helping keep Eng-Tips Forums free from inappropriate posts.
The Eng-Tips staff will check this out and take appropriate action.

Reply To This Thread

Posting in the Eng-Tips forums is a member-only feature.

Click Here to join Eng-Tips and talk with other members! Already a Member? Login



News


Close Box

Join your peers on the Internet's largest technical engineering professional community.
It's easy to join and it's free.

Here's Why Members Love Eng-Tips Forums:

  • Insulation thickness/surface temperature - Heat Transfer & Thermodynamics engineering (2)Talk To Other Members
  • Notification Of Responses To Questions
  • Favorite Forums One Click Access
  • Keyword Search Of All Posts, And More...

Register now while it's still free!

Already a member? Close this window and log in.

Join UsClose

Insulation thickness/surface temperature - Heat Transfer & Thermodynamics engineering (2024)

References

Top Articles
Latest Posts
Article information

Author: Velia Krajcik

Last Updated:

Views: 5438

Rating: 4.3 / 5 (74 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Velia Krajcik

Birthday: 1996-07-27

Address: 520 Balistreri Mount, South Armand, OR 60528

Phone: +466880739437

Job: Future Retail Associate

Hobby: Polo, Scouting, Worldbuilding, Cosplaying, Photography, Rowing, Nordic skating

Introduction: My name is Velia Krajcik, I am a handsome, clean, lucky, gleaming, magnificent, proud, glorious person who loves writing and wants to share my knowledge and understanding with you.